Raytherm® - Type H
Job:
Engineer:
Contractor:
Prepared By:
Model:
Hydronic Heating Boilers
Commercial
Models 2100-4001 (Indoor)
Date:
EFFICIENT
ꢀ 82% thermal efficiency – highest of any atmospheric
boiler available today
THERMAL SHOCK PROOF
ꢀ Twenty-year warranty against thermal shock damage
up to 150°F differential
ꢀ Maximum operating temperature: 230°F
LIGHTWEIGHT
ꢀ A floor load of 70 lbs./sq. ft. or less
HIGH RECOVERY
ꢀ Cuts fuel costs substantially because the standby and
radiation losses normal to other boilers and tank-type
water heaters are eliminated
LOW WATER OPERATING TEMPERATURE
ꢀ Operates with water temperature as low as 105°F
without condensing
Fig. 8184
Heat Exchanger
Gas Control Train
Temperature Controllers
ƒ
ASME Inspected and Stamped
160 PSIG
National Board Approved
Headers
Glass-lined Cast Iron – Standard
Bronze – Option A-1
Finned Tubing
ƒ
ƒ
ƒ
ƒ
ƒ
Manual Main Gas Shut-off Cock
B-7 Modulating
B-5 Modulating, Outdoor Reset
B-6 Two-stage
Main Gas Pressure Regulator
Redundant Safety Shut-off Valve
Control Valve
ƒ
ƒ
B-
Four-stage Digital
Firing Mode
Y-241 Electronic Sequencer,
1-4 Stages
Y-281 Electronic Sequencer,
1-8 Stages
On/off (H4)
ƒ
Two-stage Firing (H3)
Four-stage Firing (H9)
Motorized Modulation (H2)
B-6000 (H6)
Copper – Standard
Cupro Nickel – Option A-3
ASME Steel Tube Sheet
Silicone O-Rings
60 PSIG ASME Pressure Relief Valve
Temperature and Pressure Gauge
(Boiler)
Additional Safety Controls
ƒ
ƒ
ƒ
ƒ
F-9 Low Water Cut-off Probe
ƒ
ƒ
Fuel
I-1
High Limit Control,
Auto Reset
Natural Gas
Propane Gas
Design Certified ANSI Z21.13/
CSA 4.9
S-1 Low Gas Pressure Switch
S-2 High Gas Pressure Switch
ƒ
ƒ
Water Connections
Left Hand – Standard
Right Hand – Option A-6
Flow Configuration
Construction
ƒ
ƒ
ƒ
ƒ
ƒ
Front Controls
Regulatory Agency Requirements
Stainless Steel Burners
Polytuf Powder Coat Finish
Built-in Draft Diverter
Draft Inducer
Two-pass (Standard)
Single-pass (Cast Iron Only)
Controls
ƒ
ƒ
ƒ
ƒ
120V, 60Hz, 1 Ph Power Supply
Motorized Draft Inducer –
Option D-2
120/24V Transformer
100% Pilot Shut-off/Lockout
Electronic, Intermittent Ignition (IID)
Pilot
ƒ
ƒ
High Limit Control, Manual Reset
High Limit Control, Auto Reset –
Models 3001-4001
ƒ
ƒ
ƒ
On/Off Switch
Flow Switch
Economaster II Pump Time Delay
Catalog No.: 2000.26M
Effective: 12-1-07
Replaces: 12-1-99
|
Q See Digital Peripheral Solutions Camcorder QSM5265W Camera User Manual
Pelco Camera Accessories PT573 User Manual
Nikon 5x15D CF User Manual
Nextar NCD60C User Manual
MTX Audio Speaker 622CM User Manual
Motorola Hx550 Earset 89484N User Manual
Motorola H17 Bluetooth Earset H17 User Manual
KitchenAid KPCB348PPM User Manual
Kenwood KDC 3031G User Manual
JVC IN DASH 7 INCH WIDESCREEN MONITOR KV M706 User Manual